Intel
®
E8870 Scalable Node Controller (SNC) Datasheet 3-53
Configuration Registers
3.10.9 FSBPMEH[1:0]: Processor Bus Performance Monitor
Events HI
This register is the most significant one of the two used to select bus events. Use of the event
registers is mutually exclusive with other processor bus event registers. Each major bit field in the
register is ANDed with other major bit fields to select the event. If one field does not match, then
the counter will not count.
17:5 RW 0
Request Type (ANDed Group)
1xxxxxxxxxxxxDeferred Phase (ORed with other group qualifications,
not ANDed)
x1xxxxxxxxxxxDeferred Replies (Address range must be programmed
inactive)
xx1xxxxxxxxxxInterrupt Acknowledge
xxx1xxxxxxxxxSpecial Cycles
xxxx1xxxxxxxxCache Line Replacement
xxxxx1xxxxxxxMemory Read Current
xxxxxx1xxxxxxI/O Reads
xxxxxxx1xxxxxI/O Writes
xxxxxxxx1xxxxMemory Read Invalidates
xxxxxxxxx1xxxMemory Code Reads
xxxxxxxxxx1xxMemory Data Reads
xxxxxxxxxxx1xNon-Retryable Writes (non snooped)
xxxxxxxxxxxx1Retryable Writes (snooped)
4:0 RW 0
Cycle Length (ANDed Group)
1xxxx Length = 128 bytes
x1xxx Length = 64 bytes
xx1xx Length = 32 bytes
xxx1x Length = 16 bytes
xxxx1 Length =< 8 bytes
Device: NodeID
Function: 3
Offset: ACh (FSBPMEL0), ECh(FSBPMEL1) (Continued)
Bit Attr Default Description
Device: NodeID
Function: 3
Offset: B0h (FSBPMEH0), F0h(FSBPMEH1)
Bit Attr Default Description
31:19 RV 0 Reserved
18:15 RV 0 Reserved
14:13 RW 0
Processor Thread (If Supported by Processor)
Note: If Threads are not supported by the processor select 11 for this field.
01 - Thread0
10 - Thread1
12:11 RW 0
Core ID (If Supported by Processor)
Note: If Core ID is not supported by the processor select 11 for this field.
01 - Core 0
10 - Core 1
10:9 RW 0
Local or Remote
Local node access versus remote node accesses from the processor bus.
01 - local only
10 - remote only
Vue de la page 82
1 2 ... 78 79 80 81 82 83 84 85 86 87 88 ... 239 240

Commentaires sur ces manuels

Pas de commentaire

Summit Umgebungsthermometer Benutzerhandbücher

Die Liste der Summit Umgebungsthermometer -Produkte enthält 2 Benutzerhandbücher für 2 diese Modelle. Alle PDF-Benutzerhandbücher können heruntergeladen oder online angezeigt werden.

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
ALARM
Bedienungsanleitung   Summit ALARM AccuColdAlarmInstructions3-4-15, 4 Seiten
BKRF15W
Bedienerhandbuch   TRACEABLE THERMOMETER/ALARM USER MANUAL AL-3, 4 Seiten